New Products Motor Protection Relay with UL Certificate

New Products Motor Protection Relay with UL Certificate

Basic Data Dimension(mm) 32×35.5×16.five
Bodyweight ( g ) ≈35g
Speak to Arrangement 1A/1B
Get in touch with Material AgSnOtwo
Ambient Temperature -45~+85ºC
Vibration 10~50Hz,.075mm
Shock 1000m/s²,(100g)
Specification Information Nominal Voltage nine~36VDC
Electrical power Consumption <1.5W
Working Voltage seven.2V
Max. Motor Voltage 36V
Max. Switching Existing 90A
Surge Current 2500A/10ms
Motor Resistance(R±15%) 60Ω
Get in touch with Voltage <60mV
Get in touch with Resistance <0.6mΩ
Dielectric Strength Motor to Speak to >4000VAC   1min
Across Open Make contact with >2000VAC   1min
CZPTal Daily life >10000cycles
Mechanical Existence >100000cycles
Pulse Time 100ms~150ms
Choosing-up Time <65ms
Release Time <65ms
Insulation Resistance >1000MΩ(500VDC)

          Cautions of Latching Relay:

             1.Ideas of relay’s enter
            (1)Polarity-Please check out the polarity inside of of our technological specification, if single coil then”+ -” or “- +”are fine,

            you can adjust it by a single pulse.If double coil then it is required to validate “-+-” or “+-+”ahead of leaving the our manufacturing unit.

            (two)Driving-Remember to energize the relay at our recommend pulse width, rated voltage for reputable overall performance, if one.five

            occasions or 2 times of price or reduce driving situation plz verify with our engineer.
            (3)Relays’contact status might be transformed in the course of transportation or installation because of to influence of external force,
            therefore make sure you reset to the essential status.

 

            2.Ideas of relay’s output
            (one)When picking the relay with difficult connection,make sure you stay away from the exterior force on load terminals in the course of or right after

            the set up.

            (2)When the relay will be connected with screw or bolts to the relays’ terminals, plz make sure your connection is

            mounted and avoid relay from damages or other basic safety issues owing to temp. Increase..

            (3)The sampling signal wires of merchandise are minimal, remember to do not pull or torque in the course of set up.

New Products Motor Protection Relay with UL Certificate